This was a large project spreading across 6 months in Kentisbeare, Cullompton which included the supply and installation of a new ground source heat pump, 300m2 of underfloor heating to the ground floor, radiators through upstairs and in total there were 4 new bathrooms as well.

The underfloor heating pipes in the lounge were set at 100mm centres, closer than normal, typically at 150mm centres when using a heat pump, the extra pipe installed was mainly down to the sheer size of the room which was 150m2 had a very large amount of glazing with a ceiling height of just over 5m to the ridge. Even with these challenges we were able to keep the house warm whilst having very low heating bills and this was down to a well designed and installed system. Customer is very happy with the installation.